Highlights
- Intuitive LCD interface
- High frequency design
- Auto recognition of external batteries
- Predictive replace battery date
- Green mode
- Energy meter
- Outlet group control
- Sequenced shutdown and restart
- Load shedding
- Audible alarms
- Pure sine wave output on battery
- Multiple switched outlet groups
- Wide input voltage range
- Battery failure notification
- High online efficiency
- LED indicators
- Overload protection
- Cold-start capable
- Hot-swappable batteries
- Disconnected battery notification
- Automatic self-test
- Automatic restart of loads after UPS shutdown
- Adjustable voltage-transfer points
- Adjustable voltage sensitivity
- Audible alarms
- User-replaceable batteries
- USB connectivity
- Serial connectivity
- Scalable runtime
- Power conditioning
- Network manageable
- Frequency and voltage regulation
- Adjustable voltage sensitivity
- Predictive failure notification
Marketing description
Intelligent and efficient network power protection from entry level to scaleable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
Product Features
- Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. - Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. - APC USB communications
Enables communications with SMX, SMT, SRT and SURTD Smart-UPS models using historical APC proprietary USB usages. - Audible alarms
Provides notification of changing utility power and UPS power conditions - Auto recognition of external batteries
UPS recognizes when external battery packs are attached and automatically adjusts runtime. - Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power. - Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced. - Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance - Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models). - Cold-start capable
Provides temporary battery power when the utility power is out. - Disconnected battery notification
Warns when a battery is not available to provide backup power. - Energy meter
Provides actual kilowatt hours of usage for energy conscious users. - Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. - High frequency design
Reduces or eliminates bulky transformers resulting in lighter units for ease of handling. - High online efficiency
Reduces utility costs, generates less heat. - Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced - Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys. - Load shedding
Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups). - Multiple mounting methods
Allows for standardization on one product for use in different environments. - Multiple switched outlet groups
Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding. - Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded. - Outlet group control
Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups). - Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning. - Preinstalled network management card
Provides for remote management and control of the UPS over a network out of the box. - Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics. - Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment. - Safety-agency approved
The UPS is UL1778 Listed - Scalable runtime
Allows additional run time to be quickly added as needed. - Sequenced network shutdown and reboot
Customize network shutdown and reboot sequence of connected servers and UPSs. - Serial connectivity
Provides management of the UPS via a serial port. - StruxureWare Data Center Expert compatible
Enables centralized management via StruxureWare Data Center Expert. - Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature. - USB connectivity
Provides management of the UPS via a USB port (not available on all models). - User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
What's in the Box
- CD with software
- Documentation CD
- Installation guide
- Network management card
- Rack mounting brackets
- Rack mounting hardware
- Rack mounting support rails
- Smart UPS signalling RS-232 cable
- USB cable