Highlights
- Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys
- Reduces or eliminates bulky transformers resulting in lighter units for ease of handling
- UPS recognizes when external battery packs are attached and automatically adjusts runtime
- Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning
- Patent-pending operating mode that bypasses unused electrical components in good power conditions
- Provides actual kilowatt hours of usage for energy conscious users
- Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime
- Designed for harsh electrical environments to save battery life
- Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Reduces utlility costs, generates less heat
- Provides easy-to-read status of the unit and utility power conditions
- Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload
- Provides temporary battery power when the utility power is out
- Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Automatically starts up the connected equipment upon the return of utility power
- Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications
- Provides notification of changing utility power and UPS power conditions
- Prolongs battery life by regulating the charge voltage according to battery temperature
- Automatically starts up the connected equipment upon the return of utility power
- Provides remote power management of the UPS over the network
- Quickly understand unit and power status with visual indicators
- Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Enables a quick recovery from overload events
- Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation
Marketing description
Intelligent and efficient network power protection from entry level to scalable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
Product Features
- Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. - Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. - Audible alarms
Provides notification of changing utility power and UPS power conditions - Auto recognition of external batteries
UPS recognizes when external battery packs are attached and automatically adjusts runtime. - Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power. - Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced. - Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance - Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models). - Cold-start capable
Provides temporary battery power when the utility power is out. - Disconnected battery notification
Warns when a battery is not available to provide backup power. - Energy meter
Provides actual kilowatt hours of usage for energy conscious users. - Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. - Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. - High frequency design
Reduces or eliminates bulky transformers resulting in lighter units for ease of handling. - High online efficiency
Reduces utility costs, generates less heat. - Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced - Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging. - Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys. - LED Indicators
Provide easy-to-read status of the unit and utility power conditions. - Load shedding
Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups). - Multiple switched outlet groups
Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding. - Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded. - Outlet group control
Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups). - Overload protection
Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload. - Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances. - Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement. - Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning. - Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics. - Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment. - Safety-agency approved
The UPS is UL1778 Listed - Scalable runtime
Allows additional run time to be quickly added as needed. - Sequenced network shutdown and reboot
Customize network shutdown and reboot sequence of connected servers and UPSs. - Serial connectivity
Provides management of the UPS via a serial port. - SmartSlot
Customize UPS capabilities with management cards. - StruxureWare Data Center Expert compatible
Enables centralized management via StruxureWare Data Center Expert. - Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature. - USB connectivity
Provides management of the UPS via a USB port (not available on all models). - User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) - Wide input voltage range
Designed for harsh electrical environments to save battery life.
What's in the Box
- CD with software
- Documentation CD
- Installation guide
- Rack mounting brackets
- Rack mounting hardware
- Rack mounting support rails
- Removable support feet
- Smart UPS signalling RS-232 cable
- USB cable
- Web/SNMP management card